Experience the ultimate in convenience with x 10 control of low-voltage devices like sprinkler valves, door strikes, garage door openers, thermostats and more Depending on your application, the x 10 Universal Module can close a contact momentarily when an ON signal is sent, or indefinitely until an OFF signal is sent. It can even beep when responding to signals, if you choose. Rated for 5A, 24VDC (15A, 120VAC if properly insulated). Responds to ALL OFF command. Important Note: Please use common sense and safety precautions when automating garage door openers and other machinery. Although most garage door openers have built-in safety features, like IR beams or automatic reverse when something blocks its path, operating one that's not within your line of sight may cause property damage, bodily harm or worse. Read More
Description: Altronix ACM8 distributes one (1) 12 to 24 volt AC or DC input over eight (8) independently controlled fuse protected outputs. The outputs can also be coofigured as dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. It will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both fail-safe and fail-secure modes. The ACM8 is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, HVAC Shutdown, Elevator Recall or maybe used to trigger other auxiliary devices. The fire alarm disconnect can Read More
The MOM5 multi output power distribution module converts one (1) non-power limited DC voltage input to five (5) power limited outputs. Each output will route power to a variety of access control hardware and devices which includes Mag Locks, Electric Strikes, Magnetic Door Holders, etc... These outputs will operate in both fail-safe and fail-secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay will enable HVAC Shutdown, Elevator Recall or trigger auxiliary devices. Specifications: NFPA72 compliant. Class 2 outputs. 12VDC or 24VDC Operation. Five (5) individual power limited outputs. Current limit is 2.5 amps @ 12VDC or 24VDC per output. Fire Alarm Panel or Access Control System trigger inputs. (N.O. or N.C. supervised trigger input and polarity reversal trigger input). Red LEDs indicate condition of each power output. Read More
Altronix ACM8CBE distributes one (1) 12 to 24 volt AC or DC input over eight (8) independently controlled class2 power limited circuit breaker protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. It will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both fail-safe and fail-secure modes. The ACM8CBE is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, HVAC Shutdown, Elevator Recall or maybe used to trigger other auxiliary devices. The fire alarm disconnect can be configured for the following mode Read More
The KTD-415 initiates local call-up of up to 16 preset positions on a CyberDome® or other compatible PTZ (pan/tilt/zoom) receiver with preset positioning capability.FEATURES:16 dry contact connectionsAutomatic call-up of presets 0 to 15Site addressableOutput relay for alarm interfaceCustom PTZ controlRemovable terminal stripCompact: 9 x 3.15 x 1.11 inchesWall mountableEasy to installEconomicalPDF Spec Sheet Read More
The AXIS 243Q Blade Video Server enables high resolution, full frame rate video surveillance and remote monitoring in MPEG-4 or Motion JPEG on all four channels. The video server converts analog video into high quality, de-interlaced digital video, and can deliver the highest resolution, 4CIF, at 30/25 (NTSC/PAL) frames per second.The AXIS 243Q Blade allows for powerful event management with multi-window motion detection, as well as inputs/outputs for connecting external relays and sensors for activating lights, locking/unlocking doors etc. Pre- and post-image alarm buffering secures images just before and after an alarm. A comprehensive set of security features, including multiple user access levels, HTTPS encryption, possibility to disable unused network services for example ftp, IEEE802.1X and IP address filtering, ensures secure video handling and configuration. In addition, the AXIS 243Q has support for Quality of Service (QoS) which helps secure the necessary bandwidth for stream Read More
The VS5004/VS5008 are low cost, desktop, sequential switchers designed to switch four or eight cameras manually or automatically to one or two monitors and to respond automatically to alarm inputs. The VS5004 is shipped as a homing unit (one monitor output) and can be converted to a bridging unit (two monitor outputs). The VS5008 has an added bridging amplifier that allows the VS5008 to function as a homing or bridging unit without the need for conversion. If the MON2 output only is used, the VS5008 functions as a homing unit. If both MON1 and MON2 outputs are used, it functions as a bridging unit.FEATURES:120 or 230 VAC Input4 or 8 Inputs (Terminating or Looping)Single Output (VS5104/VS5108)Dual Outputs (VS5004/VS5008)Alarm Inputs (VS5004/VS5008)For use with Color or B-W CamerasCapable of Operating on 12 VDC for Use in Mobile ApplicationsPDF Spec Sheet Read More
This unit distributes and switches power to access control systems and accessories. It converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. Read More
Altronix ACM8CB distributes one (1) 12 to 24 volt AC or DC input over eight (8) independently controlled class2 power limited circuit breaker protected outputs. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. It will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both fail-safe and fail-secure modes. The ACM8CB is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, HVAC Shutdown, Elevator Recall or maybe used to trigger other auxiliary devices. The fire alarm disconnect can be configured for the following modes; Read More
Power Supply / Charger- 24VDC @ 10 Amp with ACM8 Power Controller Fire/Access interface installed. Fuse protected outputs. cULus Listed. Access Control (UL 294). With grey enclosure 15.5"H x 12"W x 4.5"D, cam lock and transformer. Read More
Activates or Deactivates Auxiliary Devices 1 Set of Form "C" Contacts For Use with Multiple Station Alarms Acts As Power Supply For Use with Smoke Alarm/Heat Detector Products, Manufacturer: Kidde Read More
The VS5004/VS5008 are low cost, desktop, sequential switchers designed to switch four or eight cameras manually or automatically to one or two monitors and to respond automatically to alarm inputs. The VS5004 is shipped as a homing unit (one monitor output) and can be converted to a bridging unit (two monitor outputs). The VS5008 has an added bridging amplifier that allows the VS5008 to function as a homing or bridging unit without the need for conversion. If the MON2 output only is used, the VS5008 functions as a homing unit. If both MON1 and MON2 outputs are used, it functions as a bridging unit.FEATURES:120 or 230 VAC Input4 or 8 Inputs (Terminating or Looping)Single Output (VS5104/VS5108)Dual Outputs (VS5004/VS5008)Alarm Inputs (VS5004/VS5008)For use with Color or B-W CamerasCapable of Operating on 12 VDC for Use in Mobile ApplicationsPDF Spec Sheet Read More
The VLC200T is our low-cost up the coax (UTC) switcher/controller, designed for either desktop or rack mounting. It has four video and alarm inputs, and is expandable, in increments of four, up to a maximum of 16 (VL200E option). There are also three video and two alarm contact closure outputs. An RS232 port is provided to interface with a P.C., or for master/slave connections. The VLC200T controls all VIDEOLARM UTC pan/ tilts and is compatible with several multiplexers. It comes complete with auto scan, zoom, focus, and three auxiliary controls (one latching).FEATURES:Up the coax control of camera, pan/tilt and lens functionsExpandable from 4 to 16 camera inputsUser programmable sequential switchingIndependent dwell setting for each camera positionCapable of master/slave confi gurationsMemory backup for programmed functionsAccepts up to 16 alarm inputsTwo alarm contact closure outputsOptional expansion boards for video loop throughPDF Spec Sheet Read More
Altronix ACM8E distributes one (1) 12 to 24 volt AC or DC input over eight (8) independently controlled fuse protected outputs. The outputs can also be configured as dry form "C" contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. It will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both fail-safe and fail-secure modes. The ACM8E is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, HVAC Shutdown, Elevator Recall or maybe used to trigger other auxiliary devices. The fire alarm disconnect can be configur Read More
Adjustable entry/exit delay Fail safe arming Bell cut-off auto restore 24 hour latching panic circuit Four wire remotes Built-in battery charger Built-in pulse stretcher Delay loop back-up circuit Regulated voltage output Dry contacts rated 5A Remote instant/delay switch Full static and lightning protection Read More
eBay offers you smart deals and the widest selection, ranging from the everyday basics to things that are as unique as yourself. With millions of items to choose from, great deals are always just a click away. Read More
Interrogator Two-Way Voice Module for Simon and Caregard: Add Additional Remote Two-Way Voice Capability to a Simon 3 Two-Way Voice Panel. Gives the Central Station Operator the Ability to Hear What is Happening During an Alarm and to Speak Directly to t Read More
SCORPIO SR-i600 ALARMThe all-new SR-i600 is the first two-way FM security system designed specifically for the motorcycle industry. By utilizing High Frequency RF technology, it is capable of sending and receiving data from up to ½ mile away from the motorcycle. The miniature hand held transceiver incorporates an interactive a LCD display that instantly confirms all commands and alarm triggers with easy to understand icons and text.Security features include: Dual axis accelerometer – detects impact and inclination Waterproof design meets OEM specifications Selectable audible/vibrating alerts Integrated 125 dB programmable multi-tone siren Violation display with time stamp Range Confirmation Signal (RCS) Available factory plug-in connector kits Additional Features Include: Two-Way FM Transceiver Alphanumeric LCD display with backlight Ultra low power drain Main Control Module Built-in Analog Devices ADXL202 accelerometer Ignition protection Range Confirmation Signal (RCS) Battery safeguard with “sleep mo Read More